Purified water for the Aquacare Pro 5L autoclave and micromotor

  • Pharmaceutical-grade Purified Water (Official Pharmacopoeia)
  • Water for autoclaves, spray micromotors and professional equipment
  • Helps to limit the build-up of limescale
  • Helps to preserve circuits, solenoid valves and internal components
  • Chemical stability for up to 18 months from the date of manufacture
  • 5-litre professional container

Intelligent Assistant

Ask a question about this product

Ref: AF889



Log in to visualise prices and purchase

Prices on Tecniwork.it are visible after logging into the website reserved to professionals only.

Discover also:

Purchase securely

Thousands of satified customers

Quick delivery

in 2/3 working days
Product description

Tecniwork’sAquacare Pro isa purified water (F.U.) formulatedfor use in autoclaves, spray micromotors and professional equipment requiring water of a high degree of purity.

Thanks to an advanced purification process and compliance with the strict requirements of the Official Pharmacopoeia, it offers controlled chemical and microbiological characteristics. 

It helps to maintain the efficiency of the equipment and to minimise the formation of limescale deposits in internal circuits.


What is Purified Water F.U.?

Purified Water F.U. (Official Pharmacopoeia) is water that meets the strict chemical and microbiological purity requirements established by the Italian Official Pharmacopoeia. It is intended for pharmaceutical preparations and for use in clinical and laboratory settings. Aquacare Pro complies with these standards and guarantees controlled quality characteristics. This makes it ideal for use in autoclaves, spray micromotors and professional equipment requiring water of a high degree of purity. 


How can limescale and deposits be prevented in an autoclave?

Using suitable water is essential for preserving the autoclave’s internal circuits. 

Aquacare Pro is purified water for autoclaves that helps to limit the build-up of limescale deposits on heating elements, solenoid valves and hydraulic circuits. Keeping the internal components clean promotes consistent heat transfer, reduces the risk of blockages and helps to maintain the equipment’s efficiency over time. 


Why is water conductivity important for autoclaves?

Conductivity is an indicator of the amount of dissolved mineral salts in the water. A very low value, such as the 0.9 µS/cm of Aquacare Pro, indicates a high degree of purity. It helps to limit the build-up of deposits inside the autoclave. Aquacare Pro also has a resistivity of 1.1 MΩ·cm and retains its chemical properties for up to 18 months from the date of manufacture. 


Why choose the 5-litre size?

The 5-litre container is designed for daily professional use. It provides a sufficient quantity of water to regularly supply the autoclave, reducing the frequency of top-ups, whilst remaining practical to carry, pour and store. 


What are the risks of not using high-quality purified water in professional equipment?

Using uncertified water or ordinary tap water exposes the equipment to serious operational risks. The mineral salts and micro-contaminants dissolved in it can, over time, cause corrosion of the heating elements and blockage of the solenoid valves. Choosing purified water that complies with the Official Pharmacopoeia (F.U.) helps to prevent unexpected technical faults, in line with the guidelines normally provided by manufacturers of professional equipment. 


Why choose Aquacare Pro instead of standard demineralised water for autoclaves?

Not all demineralised water is the same. Many products available on the market are intended for domestic use, such as irons or humidifiers. They are not necessarily produced to the standards required for use in professional equipment.

Aquacare Pro is a pharmaceutical-grade Purified Water (Official Pharmacopoeia), specifically designed for use in autoclaves, spray micromotors and professional equipment.

Each batch undergoes testing to verify key parameters such as conductivity, total organic carbon (TOC), bacterial endotoxins and the absence of contaminants. This consistent quality helps to minimise the build-up of deposits, protect internal components and maintain the equipment’s efficiency over time. 


What technical characteristics make Aquacare Pro a professional-grade purified water?

  • Conductivity controlled at 0.9 µs/cm and resistivity of 1.1 MΩ·cm 
  • TOC reduced to less than 0.5 ppm  
  • Absence of heavy metals and silicone contaminants (Cadmium, Chromium, Iron < 0.10 ppm)  
  • Bacterial endotoxin level below 0.25 EU/ml  
  • Mechanical filtration process at 0.45 microns.
  • Chemical stability verified for up to 18 months from the date of manufacture
  • Professional format that is easy and practical to use in day-to-day work
Details

Technical specifications


Physical appearance: Clear, colourless and odourless liquid  

pH value: 5.5 to 7  

TOC (Total Organic Carbon): < 0.5 ppm  

Electrical conductivity: 0.9 µs/cm  

Electrical resistivity: 1.1 MΩ·cm   

Microbiological count: < 100 CFU/ml  

Bacterial endotoxins: < 0.25 EU/ml  

Microfiltration threshold: 0.45 microns  

Chemical suitability: Complies with standards for chlorides, nitrates, sulphates, calcium and magnesium  

Shelf life: 18 months from the date of manufacture 

Hints

How to use and store Aquacare Pro correctly

Close the container tightly after each use to preserve the water’s quality.

Store the product in a cool, dry place, away from direct light and sources of heat.

Do not mix Aquacare Pro with tap water or any other type of water, to ensure its purity remains unaltered.